Aug 04, 2022 Leave a message

The Role Of Each Temperature Section Of The Reflow Soldering Temperature Curve

The reflow soldering temperature curve refers to the curve of the temperature of a pin on the component changing with time when the SMD component passes through the reflow soldering furnace. The temperature profile is a function of the temperature applied to the assembled components as a function of time Y=F(T), and is represented as a curve of the temperature at a given point on the printed circuit board during the reflow process as a function of time. The reflow soldering temperature curves you see are divided into four temperature zones, so what are the functions of these four temperature zones? Share it here.

1. The role of the preheating section of the reflow soldering temperature curve

The purpose of this temperature zone is to heat the circuit board at room temperature as soon as possible, but the rapid heating cannot be so fast that the board or parts are damaged and cause the loss of solvent in the flux. The usual heating rate is 1-3 ℃ / sec. In actual production, it is not required that the selected curve of each point reach an ideal situation. Restrictions will cause the temperature curve method at some points to meet the requirements. At this time, the influence of each component on the function of the entire circuit board must be selected as a favorable reflow parameter.

2. The function of the heat preservation section of the reflow soldering temperature curve

The boiling point of the solvent is between 125-150°C. The solvent will evaporate continuously from the holding period, and the resin or rosin will soften and flow at 70-100°C. Once melted, the resin or rosin can spread rapidly on the surface to be welded and dissolve in it. The active agent flows and reacts with the surface oxides of the lead-tin powder to ensure that the lead-tin powder is clean when the welding section is welded.

The main purpose of the heat preservation section is to ensure that all components on the circuit board reach the same temperature before entering the welding section. The heat absorption capacity of the components on the circuit board is usually very different. Sometimes it is necessary to extend the heat preservation period, but too long heat preservation The cycle may lead to the loss of flux, resulting in sufficient bonding and wetting in the fusion zone, weakening the tinning ability of the solder paste, and too fast a temperature rise rate will lead to rapid vaporization of the solvent, which may cause blow holes, solder balls and other defects, and the short holding period can make the activator fully exert its effect, and it may also cause the unbalance of the preheating temperature of the entire circuit board, resulting in defects such as non-stick tin, disconnection after soldering, and voids in solder joints, so it should be The length of the holding period and the temperature value are determined according to the design of the circuit board and the convection heating capacity of the reflow oven.

Generally, the temperature of the heat preservation section of the reflow soldering temperature curve is between 100-160 °C, the rising rate is less than 2 degrees per second, and there is a platform around 150 °C for about 0.5-1 minute, which helps to reduce the end area of the soldering section. reduced to small.

3. The role of the reflow section of the reflow soldering temperature curve

The high temperature of the reflow section is 245 degrees, the low temperature is 200 degrees, and the time to reach the value is about 35/S; the heating rate of the reflow area is: 45 degrees/35S=1.3 degrees/S According to (how to set it correctly temperature curve), it can be seen that the time for this temperature curve to reach the value is too long. The whole reflow time is about 60S.

4. The function of cooling section of reflow soldering temperature curve

The time of the cooling section of the reflow soldering temperature curve is about 100S, the temperature is reduced from 245 degrees to about 45 degrees, and the cooling speed is: 245 degrees - 45 degrees = 200 degrees / 100S = 2 degrees / S.