Aug 11, 2022 Leave a message

Three Common Fault Maintenance Methods For Reflow Soldering Machines

Reflow soldering machine suppliers generally focus on diagnosing equipment failures and then replacing the small accessory units they can supply. The users of reflow soldering machines focus on the timely repair of the equipment to ensure no downtime, and then buy small accessory units. Here are three common troubleshooting methods for reflow soldering machines.

1. Reasons and maintenance of the unstable speed of the conveyor belt of the reflow soldering machine

Cause of failure: The carbon brush of the DC speed regulating motor is worn, and there is too much carbon powder.

Repair solution: replace the carbon brush, clean the toner.

2. The furnace temperature of the reflow soldering machine is not stable, and there are random fluctuation reasons and maintenance

Cause of failure: On the control board, the temperature analog signal is converted into a digital signal, which is amplified by the IC (6N137), resulting in a noise signal.

Repair solution: replace IC (6N137)

3. The temperature of the reflow soldering machine is normal, but the solder paste does not reflow

Cause of failure: The heater fan does not turn, because the motor in it is damaged and short-circuited, and switches #34 and #35 are tripped.

Maintenance solution: replace the motor, reset the switch.

The quality of the reflow soldering machine maintenance personnel is very important, and they should have the knowledge of electromechanical, automatic control, computer and so on. SMT equipment is highly automated control equipment, and the technology used is actually more advanced, so another quality of maintenance personnel is to accept new knowledge and technology quickly.

Reflow soldering machine maintenance personnel should have the minimum tools: multimeter, oscilloscope, IC data or can check relevant data on the Internet in real time. Generally, don't expect the random machine to have circuit schematic diagrams such as control boards and driver boards. You can only rely on your own analysis and draw. Part of the circuit diagram to analyze the control circuit and find the problem.